+86 183 02053458

jane@dgzhongzhi.com

Walk-in high and low temperature humid heat test chamber

Walk-in high and low temperature wet heat test chamber is a necessary test equipment in aviation, automotive, home appliances, scientific research and other fields, used to test and determine the parameters and performance indicators of electrical, electronic and other products and materials after temperature environment changes in high temperature, low temperature, alternating humidity and heat degree or constant test.

Share:

Description

All materials, parts, components, raw materials, etc., whether domestic or imported, are environmentally friendly products, not only the energy consumption only accounts for 80% of similar products, but also the sound absorption and noise reduction methods are used in the whole structure and different places in the mechanical work process to reduce the noise of the entire equipment and improve customer use test.

Features

The appearance can be matched with different colors or choose all stainless steel design according to the interior design, the interior space is made of SUS304# and stainless steel;

Rectangular laminated glass viewing window, can be used in the test to observe the test product, the window with anti-perspirant electric heater device can prevent water condensation water droplets;

Indoor installation of explosion-proof lights, the test can clearly observe the product test status, the bottom of the laboratory installation of non-slip aluminum plate safe use;

Double-layer heat insulation sealing strip of the door can effectively isolate the internal temperature leakage;

With pure water filter unit to filter tap water directly, no need to manually add water, easy to use;

Refrigeration dehumidification system adopts imported brand compressor, which has the advantages of energy saving, low noise, low energy consumption and stable performance, and adopts environmental protection refrigerant (R23, R404a);

The controller adopts imported LCD display screen, which can display the measured value and set value, time, etc.

The controller has multi-segment program editing and temperature and humidity can be QUICK or SLOPE control;

TEM2700 7.5-inch true color LCD screen with RS-232/RS-485 communication interface, 2GB standard SD memory card, can be connected to Ethernet use; TEM880 Watch 5.7-inch color display,

Including RS-232/RS-485 communication interface (optional on request);

The bottom of the machine adopts channel steel welded into a network structure to increase the load bearing, the use of never deformed, the bottom of the integrated laboratory is installed with moving casters and positioning foot cups, and the bottom of the assembled laboratory is directly installed with channel steel

Installed on the lab floor.


Humidity Control Range

Walk-in high and low temperature humid heat test chamber

Core Parameters

Walk-in high and low temperature humid heat test chamber
ModelCZ-A-4000(D~G)CZ-A-8000(D~G)CZ-A-10000(D~G)CZ-A-15000(D~G)CZ-A-20000(D~G)CZ-A-25000(D~G)CZ-A-30000(D~G)CZ-A-40000(D~G)
Inner Dimension WxHxD(mm)1500x1800x15002000x2000x20002500x2200x20003000x2000x25004000x2000x25004000x2500x25004000x2500x30005000x2500x3200
Outer Dimension WxHxD(mm)2500x2100x17003100x2300x22603600x2300x22604100x2300x27605100x2300x27605100x2800x27605100x2800x35006100x2800x3500
Temperature Range-70℃~+80℃(A1Above 80℃ is customized)(D:-40℃ G:-70℃)
Humidity Range20%~95%R.H.(10%-98%R.H/5%~98%R.H is special customized)
Temperature Humidity Resolution/Uniformity0.01℃;0.1%R.H./±1.0℃;±3.0%R.H.
Temperature Humidity Control Accuracy/Fluctuation±1.0℃;±2.0%R.H./±0.5℃;±2.0%R.H.
Heating/Cooling RateHeating rate is 3.0℃/min, cooling rate is   1.0℃/min(2℃~15℃/min is special customized)
Inner/Outer MaterialCold rolled steel plate finish, inner box SUS 304# stainless steel
Insulation MaterialHigh temperature resistant high density polyester amine rigid foam insulator material
Cooling SystemOptional air/water cooled type below 10 cubic meters, water cooled type above 10 cubic meters
Protection DeviceNo fuse switch, compressor overload protection switch, refrigerant high and low pressure protection switch, over humidity and over temperature protection switch, fuse, fault warning system
Spare PartsRecorder (optional), viewing window, 50mm test hole, PL box light, partition, wet and dry bulb gauze
ControllerKorea "TEMI" or custom optional
CompressorTecumseh,France
Power3Φ380VAC±10%50/60Hz 
RemarkBelow 10 cubic meters can be selected as the whole machine structure can be mobile or warehouse board assembly structure, more than 10 cubic meters are warehouse board assembly structure



Product meets test conditions and implementation standards

GB2423.1-2008/IEC6008-2-1-2007 Low temperature test method

GB/T2423.2-2008 High temperature test method

GJB150.3A-2009 high temperature test method

GJB150.4A-2009 Low temperature test method

GB2423.22-2008 Temperature change rate test method

GBT2424.5-2006 Temperature test chamber performance confirmation

GB/T10589-2008 Low temperature test chamber technical conditions

GB/T2423.3-2008(IEC68-2-3) constant humid heat test method

GJB150.9A-2009 Wet heat test method

G/BT24234-2008/IEC6008-2-30:2005 Alternating humid heat method

GB/T5170.18-2005 Temperature/humidity combined loop test equipment verification method

GB/T10586-2006 Wet heat test chamber technical conditions

GBT2424.6-2006 Temperature/humidity test chamber performance confirmation

GBT2424.7-2006 (with load) temperature test chamber measurement